How Do You Relight a Furnace Pilot Light?

Turn the gas control knob to Off, wait at least five minutes for gas to clear, then turn the knob to Pilot, hold down the reset button or knob, and light the pilot with a long lighter or match. Once the pilot stays lit, turn the knob to On. Those are Trane's steps for furnaces with a standing pilot light when the owner's manual is not handy. If you smell gas at any point, stop, leave the house, and call your gas company from outside.
A pilot to relight is a sign of an older furnace. Trane notes that a furnace installed before 2010 may have a standing pilot light, and it adds that a standing pilot wastes natural gas. Newer gas furnaces light their burners electronically; Carrier's troubleshooting guide for one of its two-stage furnaces describes a hot surface igniter that heats up only when the thermostat calls for heat. On gas boilers, federal efficiency rules at 10 CFR 430.32 have barred constant-burning pilots on units made since September 1, 2012. This guide covers how to tell whether your furnace has a pilot, how to relight it safely, what the flame color means, and why it keeps going out.

Does Your Furnace Have a Pilot Light?
A standing pilot light is a small gas flame that burns all the time and lights the main burners when the thermostat calls for heat. Trane says it sits near the bottom front of the furnace behind an access panel, and some furnaces have a small viewing window so you can see it without removing anything.
If you see a small blue flame through the window, the furnace has a standing pilot. If there is no flame, the pilot may be out or the furnace may use electronic ignition instead. The label inside the furnace door or the owner's manual will say which. Carrier's guide describes the sequence on that type: the thermostat calls for heat, an inducer clears the vent, the igniter heats up, and then the gas valve opens. There is nothing to relight on an electronic ignition furnace, and the guide to a furnace blowing cold air explains what to check instead.
What Should You Check Before Relighting?
Start with your nose. The U.S. Consumer Product Safety Commission says that if you smell or hear gas leaking, leave the home immediately and contact your gas utility from outside. Do not operate lights, phones or other electronics inside. Do not try to relight anything.
If there is no gas smell:
Make sure the thermostat is set to heat and above room temperature.
Check that the gas supply to the furnace is on.
Look for lighting instructions on a label inside the furnace door or in the owner's manual. The manufacturer's steps take priority over any general guide, including how long to hold the reset button.
How Do You Relight a Furnace Pilot Light?
If you do not have the manual, Trane gives these steps:
Remove the furnace access door to reach the pilot.
Find the gas valve control knob, which is marked Pilot, On and Off.
Turn the knob to Off.
Wait at least 5 minutes for the gas to dissipate.
Turn the knob to Pilot.
Press and hold the reset button, or press the control knob itself on some models.
Light the pilot with a long lighter or match while holding the button.
Once the pilot is lit and stays lit, turn the knob to On.
Replace the access door.
If the pilot will not light, Trane says to wait and repeat the steps. If it still will not light, call a professional.
What Color Should a Pilot Light Be?
Blue. Trane describes a healthy pilot as a small blue flame and says that if the flame is yellow, you should call for furnace repair.
A yellow flame points to a combustion problem, and combustion problems can raise carbon monoxide concerns. CPSC recommends carbon monoxide alarms on each level of the home and outside sleeping areas, tested monthly. The carbon monoxide and furnace safety guide covers placement and warning signs. If an alarm sounds, get everyone outside and call 911.
Why Does the Pilot Light Keep Going Out?
Trane lists three reasons a pilot will not stay lit:
A draft blowing the flame out
A dirty or clogged pilot that cannot hold a steady flame
A faulty part, such as the thermocouple, the sensor that sits in the pilot flame and tells the gas valve it is safe to stay open
A pilot that goes out once after a strong gust may just need relighting. One that goes out again and again needs a technician to clean the pilot assembly or replace the thermocouple. Note when the pilot went out and anything that happened around then, such as a windstorm, a power outage or work on the gas line, since those details help narrow the cause.
Outside, keep the furnace vent clear in winter. CPSC's December 2025 safety release says to clear snow away from the outside vents of fuel-burning appliances such as furnaces so carbon monoxide does not build up in the house. The guide to preventing common furnace problems this winter also lists a dirty thermocouple and gas supply problems among the causes.
Is It Time to Replace a Furnace With a Standing Pilot?
Age is the first clue. Trane says a gas furnace lasts around 15 to 20 years, with some running up to 30, and that an older furnace installed before 2010 may have a standing pilot. Trane also notes that a standing pilot wastes natural gas, since it burns all the time whether the furnace is heating or not.
Federal minimums have moved too. Under 10 CFR 430.32, non-weatherized gas furnaces must reach 80% AFUE today, and those made on or after December 18, 2028 must reach 95%. The guide to signs it is time to replace your furnace covers the rest of that decision.
FAQ
How long should I wait before relighting a pilot light?
Trane says to turn the gas control to Off and wait at least 5 minutes for the gas to dissipate before relighting.
Is it safe to relight a furnace pilot light myself?
Trane gives homeowner steps for it, but only when there is no gas smell. If you smell gas, leave the house and call the gas company from outside. If the pilot will not stay lit after a second try, call a professional.
Why is my furnace pilot light yellow?
A yellow pilot flame is a warning sign. Trane says to call for furnace repair if the flame is yellow rather than blue.
Do newer furnaces have pilot lights?
Trane says furnaces installed before 2010 may have a standing pilot. Newer furnaces, like the Carrier model covered in its troubleshooting guide, use a hot surface igniter instead.
What is a thermocouple?
It is the small sensor in the pilot flame that tells the gas valve the pilot is lit. Trane lists a faulty thermocouple among the reasons a pilot keeps going out.
Do gas boilers still use pilot lights?
Not new ones. Federal standards have barred constant-burning pilots on gas boilers made since September 1, 2012.
Van Bremen's Heat & Air Repairs and Replaces Older Furnaces
Van Bremen's Heat & Air repairs, maintains and replaces residential and commercial furnaces from its office at 214 Stoystown Rd in Somerset, serving Somerset, Fayette, Cambria and Westmoreland Counties and Morgantown, WV. A technician can clean a pilot assembly, replace a thermocouple, or help you compare a new furnace, with financing available through Synchrony. See the heating services page and maintenance services page.
Visit Van Bremen's Heat & Air or call (814) 483-1735 today. Contact us for more information.




Comments